Structural design

CITTI Park Lübeck

Load-bearing tests on existing purlins

Facts and figures

Client:
CITTI Handelsgesellschaft mbH & Co. KG
Object:
CITTI Park Lübeck
Design:
CITTI Handelsgesellschaft mbH & Co. KG
Services:
Structural design
Test planning and execution incl. test evaluation
Special features:
  • Execution of ultimate load tests on 8 prestressed concrete purlins until complete failure
  • Determination of the maximum load capacity, the type of failure (failure with or without prior notice), the deformation behavior and the material characteristics
  • Development of a transportable test frame for sampling prefabricated beams (length up to 12 m) in the building or in the test field
  • Adaptation of the test framework to local conditions
  • Simulation of a vertically acting uniform line load over the duration of the test
  • Fulfillment of the requirements for a test-based component design through precise manufacturing conditions and a clever choice of design
  • Exclusion of external disturbance variables on data acquisition
  • Result: Confirmation of the increase in the originally specified load capacity by 30 %

Purlin tests Trebes 2016